HVAC practical Project-1 one-kanal energy-efficient home in Brewton, Alabama

Downloads

Looking for a sustainable home that harmonizes with the environment and reduces energy consumption? Explore our innovative 1-kanal energy-efficient home design in Brewton, Alabama, where we’ve engineered a modern two-story residence with a fully integrated basement that blends cutting-edge HVAC optimization with energy efficiency to redefine sustainable living.

This real-time project leverages Revit MEP to craft a 100% airtight building envelope, effectively minimizing thermal bridging and maximizing insulation. From smart HVAC systems to automated zoning, every element is carefully designed to slash energy consumption and optimize comfort in response to external environmental changes like fluctuating outdoor air quality, solar exposure, and local climate. 🔋💡

With advanced HVAC controls, smart fire detectors, and automated zoning, this home adapts to the shifting demands of the environment—ensuring superior indoor comfort while achieving net-zero energy potential. It's not just about building a house; it’s about creating a resilient, future-ready home that sets new standards for energy-efficient design. 🌞🏠

[@portabletext/react] Unknown block type "youtubeVideo", specify a component for it in the `components.types` prop

🌦️ The Climate Challenge of Brewton, Alabama

Brewton, Alabama, experiences a humid subtropical climate characterized by hot, humid summers and mild winters. The average high temperature in July is approximately 91°F (33°C), with average lows around 73°F (23°C) . Humidity levels are notably high, averaging around 71% in July, contributing to a sticky atmosphere . Annual precipitation is substantial, with the region receiving about 56 inches (1,422 mm) of rainfall each year .​

☀️ Solar Considerations

Brewton benefits from significant sunlight, with an average of 10.9 hours of sunshine per day in July . The maximum solar altitude reaches approximately 82.5° in summer, indicating strong solar energy potential . This abundant sunlight is advantageous for passive solar heating and natural lighting strategies.​

🌬️ Outdoor Air Quality Index (AQI)

As of the latest data, Brewton's Air Quality Index (AQI) is categorized as "Moderate," with a PM2.5 concentration of 15 µg/m³ . While this level is generally acceptable for the average person, sensitive individuals may experience health effects. It's advisable to monitor air quality forecasts and take precautions when pollution levels rise.​

⚡ Peak Conditions & HVAC Design Considerations

During peak summer conditions, Brewton can experience high temperatures exceeding 95°F (35°C) and elevated humidity levels, leading to heat indices that make outdoor activities challenging. The region's HVAC systems must be designed to handle these extreme conditions effectively. Key considerations include:​

  • Dehumidification: Essential to maintain indoor comfort and prevent mold growth.
  • Energy Efficiency: Systems should be optimized to handle high cooling loads without excessive energy consumption.
  • Ventilation: Proper ventilation is crucial to ensure air quality and comfort.
  • Solar Gain Management: Strategic window placement and shading can reduce cooling demands.​

Incorporating these elements into HVAC system design will enhance comfort and efficiency in Brewton's challenging climate.

Building Standards and Local Regulations 📋🏗️

To ensure the highest standards of safety, energy efficiency, and compliance, this project adheres to Brewton’s construction codes, based on the International Building Code (IBC), International Residential Code (IRC), and other key regulations. The City of Brewton Code Enforcement Officer ensures that every aspect of the design meets local and state standards, including energy efficiency, safety, and accessibility. The Alabama Home Builders Licensure Board and State Fire Marshal provide further oversight, guaranteeing that your home meets all required criteria.

Why This Project Stands Out 🚀

This real-time project is a testament to the future of energy-efficient homes, seamlessly integrating advanced HVAC systems, eco-friendly designs, and cutting-edge technologies. By reducing your carbon footprint and embracing sustainability, this home not only promises comfort and efficiency but also paves the way for the next generation of resilient homes.

Looking to build an energy-efficient home that adapts to its environment? This project could be your blueprint for success. Let's talk about how energy-efficient HVAC design can transform your next build! 🌍🏠

Ultimate Guide to 1 Kanal Plot Dimensions, House Footprint, and Zoning Rules in Brewton, Alabama

Discover how to maximize a 1 kanal plot—equal to about 5,445 square feet or roughly 0.125 acres (since 1 acre equals 43,560 sq ft)—for your dream home in Brewton, Alabama. This size, popular in South Asian measurements, fits perfectly as a suburban lot here. Picture a rectangular shape with a 3:4 ratio (where width is 0.75 times length) for easy planning. Here's the simple math: Let L be length, then area = L × (0.75L) = 5,445 sq ft. So, 0.75L² = 5,445; L² = 7,260; L ≈ 85.2 ft (round to 85 ft). Width ≈ 63.9 ft (round to 64 ft). Quick check: 85 ft × 64 ft = 5,440 sq ft, super close to the target!

Architectural Project  at Brewton, Alabama.

For house building, we suggest a smart footprint of 2,400 sq ft per floor (40 ft × 60 ft), stacking up to 7,200 sq ft total over basement, ground, and upper levels. This uses just ~44% of your lot, leaving 3,045 sq ft free— not wasted, but smartly reserved for essentials like green spaces and access. It matches Alabama's usual 30-50% coverage caps to handle water flow and eco-friendly rules in Brewton's steamy weather.

★ Key Zoning Setbacks in Escambia County/Brewton (Typical R-1 Zone): Local rules demand buffer zones: ≈20 ft front, 10 ft per side, 10 ft rear. For your 85 ft × 64 ft lot:

Buildable width: 64 ft - (10 ft + 10 ft) = 44 ft

Buildable length: 85 ft - (20 ft + 10 ft) = 55 ft

Max house base: 44 ft × 55 ft = 2,420 sq ft Our 2,400 sq ft pick fits snugly, tweaked for better sun capture (longer 60 ft side facing south). These buffers eat up ~2,000 sq ft total—front zone: 64 ft × 20 ft = 1,280 sq ft; sides: 2 × (85 ft × 10 ft) = 1,700 sq ft (minus corners overlap)—keeping things safe and private, as per IRC R301 standards.

• Smart Ways the Extra 3,045 sq ft Boosts Your Home:

Driveway & Parking: ≈480 sq ft (e.g., 24 ft × 20 ft for two cars), required by IRC R309 for smooth entry.

Yards & Greenery: 1,000-1,500 sq ft for sides/rear, perfect for draining Brewton's 34.61 inches yearly rain and planting shade trees like oaks to cut cooling costs.

Drainage Setup: Overlaps with yards; gentle 1-2% slope keeps water away from your sealed home shell (R-10 basement insulation via IECC R401.3).

Utility Spots: Room for HVAC units, rain collection tanks, and more, slashing energy use in hot, humid days.

This setup supercharges energy savings: The compact base limits heat leaks, while south-facing design grabs max passive sun (angles up to 82.5° in summer). It follows IRC 2015 (common locally, with 2021 tweaks nearby like Baldwin County) and IECC 2015 for top insulation. Plus, it gears up for Alabama's new 2025 home code rollout, dodging overbuild issues. Verify details with Escambia County pros (call 251-867-0305) to tweak for your spot—ideal for eco-homes with geothermal HVAC and solar perks!

Floor Plans

Basement Plan

Basement Floor Plan Architectural Project  at Brewton, Alabama.

Ground Floor

Ground Floor Plan Architectural Project  at Brewton, Alabama.

First Floor

First Floor Plan Architectural Project  at Brewton, Alabama.

HVAC Load Calculation in Revit for Brewton, Alabama Project

In this Brewton, Alabama project designed using Revit, HVAC load calculation plays a crucial role in ensuring efficient heating, ventilation, and air conditioning systems. By integrating ASHRAE standards directly into Revit space type settings, the design optimizes energy use and indoor air quality. Key parameters such as outdoor air ventilation rates, air changes per hour, lighting and power load densities, infiltration airflow, and heat gains are applied to calculate cooling and heating loads accurately. Each floor functions as a single zone for HVAC purposes, simplifying zoning while adhering to standards like ASHRAE 62.1 for ventilation and ASHRAE 90.1 for energy efficiency.

Overview of ASHRAE Standards in HVAC Load Calculation

ASHRAE standards provide the foundation for HVAC load calculation in Revit by defining minimum requirements for ventilation, heat gains, and load densities in various space types.

  • ASHRAE Standard 62.1: This standard outlines ventilation rates to achieve acceptable indoor air quality, using the Ventilation Rate Procedure (VRP). It specifies outdoor air requirements per person and per area, along with default air change effectiveness, to remove contaminants and supply fresh air. For instance, it includes rates for gyms (20 cfm/person), kitchens (varying based on exhaust needs), bedrooms (5 cfm/person), libraries (5 cfm/person outdoor air plus area-based rates), and swimming pools (7.5 cfm/person for spectators with additional humidity controls).
  • ASHRAE Standard 90.1: Focuses on energy-efficient design, influencing power and lighting load densities in load calculations. It helps determine equipment sizing by accounting for sensible and latent heat gains from occupants, lights, and appliances.
  • Integration in Revit: Revit’s energy analysis tools use these standards to simulate loads. Space types are assigned parameters like sensible heat gain (e.g., 710 Btu/h per person in gyms) and infiltration (e.g., 5-10 ACH in high-activity areas), enabling precise HVAC sizing without overdesign.

These standards ensure the Brewton project’s HVAC system balances comfort, energy savings, and compliance.

Basement Floor HVAC Load Calculation

The basement floor, treated as a single zone in Revit, includes a sports room (gym/exercise area), library, swimming pool (natatorium), and open space rest area. HVAC load calculation here emphasizes high ventilation for moisture control and activity levels, using ASHRAE-guided parameters to compute total cooling and heating demands.

basement plan

Sports Room (Gym/Exercise Area) Parameters

For the sports room, Revit settings draw from ASHRAE 62.1’s requirements for fitness spaces to handle elevated heat and moisture from physical activity.

  • Outdoor Air Ventilation: 20 cfm per person, combined with 0.06 cfm/ft² area rate, to dilute odors and CO2.
  • Air Changes per Hour: 6-8 ACH, ensuring rapid air turnover for sweat evaporation.
  • Lighting Load Density: 0.72 W/ft², contributing to internal heat gains.
  • Power Load Density: 0.6 W/ft² from equipment like treadmills.
  • Infiltration Airflow: 5-10 ACH (based on 0.5-1 ACH typical for commercial gyms), modeled as 2.0 CFM/SF in some configurations.
  • Sensible Heat Gain: 710 Btu/h per person, accounting for metabolic heat.
  • Latent Heat Gain: 1090 Btu/h per person, critical for dehumidification in exercise zones.

These values feed into Revit’s load calculation, resulting in higher cooling loads due to occupant activity.

ASHRAE standards for sports room in revit

Sitting Area (Lounge/Breakroom) Parameters

Sitting areas use ASHRAE standards for low-activity lounges, focusing on comfort ventilation.

  • Outdoor Air Ventilation: 5 cfm per person, plus infiltration considerations.
  • Air Changes per Hour: 3-6 ACH for sedentary occupants.
  • Lighting Load Density: 0.55 W/ft², minimal for ambient lighting.
  • Power Load Density: 1.0 W/ft² from electronics.
  • Infiltration Airflow: 3-5 ACH (residential-like envelope).
  • Sensible Heat Gain: 245 Btu/h per person.
  • Latent Heat Gain: 105 Btu/h per person.

This keeps loads lower, balancing the zone’s total calculation

HVAC practical Project-1  one-kanal energy-efficient home in Brewton, Alabama

Library Parameters

Library settings align with ASHRAE 62.1 for reading areas, emphasizing quiet, controlled air quality.

  • Outdoor Air Ventilation: 5 cfm per person.
  • Air Changes per Hour: 4-6 ACH; Reading: 0.96 ACH; Stacks: 1.10 ACH.
  • Lighting Load Density: Reading: 1.2 W/ft²; Stacks: 1.10 W/ft² (wait, table has Reading 0.96, but screenshot shows 1.20 W/ft²).
  • Power Load Density: Not specified distinctly, but 1.0 W/ft² general.
  • Infiltration Airflow: 3-5 ACH (commercial library envelope).
  • Sensible Heat Gain: 245 Btu/h per person (seated reading/light work).
  • Latent Heat Gain: 105 Btu/h per person.

These parameters ensure minimal disturbance while calculating ventilation loads.

ASHRAE Library Parameters

Swimming Pool (Natatorium) Parameters

Swimming pools require specialized handling per ASHRAE 62.1 for humidity and chloramine control.

  • Outdoor Air Ventilation: Spectator: 7.5 cfm/person; Pool: 0 cfm/person (but area-based at 0.06-0.48 cfm/ft² for evaporation).
  • Air Changes per Hour: 4-6 ACH (Class IV for pumps/equipment).
  • Lighting Load Density: 0.59 W/ft².
  • Power Load Density: 0.5-1.0 W/ft² (pumps/equipment).
  • Infiltration Airflow: 5-10 ACH (high due to negative pressure).
  • Sensible Heat Gain: Swimmer (athletic): 710 Btu/h; Spectator (seated): 245 Btu/h.
  • Latent Heat Gain: Swimmer: 1090 Btu/h; Spectator: 105 Btu/h.

High latent loads dominate, requiring robust dehumidification in the single zone.

In Revit, these combined parameters yield the basement’s total HVAC load, with ASHRAE ensuring compliance.

SWIMMING POOL DESIGN

Ground Floor HVAC Load Calculation

The ground floor, configured as a single zone in Revit, features two bedrooms, one sitting area, and an open kitchen with dining area. HVAC load calculation incorporates ASHRAE standards for residential-like spaces, focusing on mixed-use ventilation and heat gains.

HVAC GROUND LFOOR

2 X Bedroom Parameters

Bedrooms follow ASHRAE 62.2 for residential sleeping quarters, integrated into Revit for restful environments.

  • Outdoor Air Ventilation: 5 cfm per person.
  • Air Changes per Hour: 3-6 ACH.
  • Lighting Load Density: 0.41 W/ft².
  • Power Load Density: 0.75 W/ft².
  • Infiltration Airflow: 2-4 ACH (0.35 ACH typical residential).
  • Sensible Heat Gain: 210 Btu/h per person (sleeping).
  • Latent Heat Gain: 140 Btu/h per person.

Low activity reduces cooling demands in th

Bedroom Parameters

e zone.

Sitting Area (Lounge/Breakroom) Parameters

  • Mirrors basement sitting area, with 3-6 ACH and 245 Btu/h sensible gain per person.

Open Kitchen with Dining Area Parameters

Though primarily on upper floors, basement references align with dining standards for any shared use, per ASHRAE 62.1’s kitchen and dining rates.

  • Outdoor Air Ventilation: Kitchen: 7.5 cfm/person; Dining: 7.5 cfm/person, with additional exhaust at 10-20 cfm/person for high needs.
  • Air Changes per Hour: Kitchen: 15-30 ACH; Dining: 8-10 ACH, to manage cooking fumes.
  • Lighting Load Density: Kitchen: 1.19 W/ft²; Dining: 0.52 W/ft².
  • Power Load Density: Kitchen: 2.0-3.0 W/ft²; Dining: 1.0-2.0 W/ft² from appliances.
  • Infiltration Airflow: 10-20 ACH (high exhaust), or 3-6 ACH for seated areas.
  • Sensible Heat Gain: Kitchen (light work): 275 Btu/h; Dining (eating/seated): 245 Btu/h per person.
  • Latent Heat Gain: Kitchen: 475 Btu/h; Dining: 255 Btu/h per person.
  • In a single-zone setup, these contribute to the basement’s overall dehumidification needs..
ASHRAE standard for dinning

This zone’s loads are moderate, with kitchen activities increasing latent components.

First Floor HVAC Load Calculation

First Floor HVAC plan

The first floor, also a single zone in Revit, replicates the ground floor layout with two bedrooms, one sitting area, and an open kitchen with dining area. HVAC parameters follow identical ASHRAE standards, ensuring consistent load calculations across similar zones.

Bedroom Parameters

  • Identical to ground floor, prioritizing low infiltration for energy efficiency.

Sitting Area (Lounge/Breakroom) Parameters

  • Same as above, with focus on occupant-based ventilation.

Open Kitchen with Dining Area Parameters

  • Consistent with ground floor, using 15-30 ACH in kitchen for effective fume removal.

Uniformity in standards simplifies overall building HVAC design in Revit for the Brewton project.

HVAC Load Calculations in Revit: Detailed Breakdown for Each Zone

In this continuation of our energy-efficient home design guide using Revit MEP, we focus on the HVAC load calculations for the three-zone VAV system in Brewton. Each floor operates as a single zone with variable air volume (VAV) for optimized air distribution, incorporating direct expansion cooling coils and electric resistance heating. The calculations, based on Revit simulations, draw from ASHRAE standards like 62.1 for ventilation and 90.1 for energy efficiency to ensure accurate sizing. Below, we detail the sensible and latent loads for each zone, explain the psychrometric conditions, and provide guidance on total loads. We'll also clarify equipment selection in tons, recommend placement, and outline the complete methodology—making it easy to understand for homeowners and designers seeking HVAC load calculation in Revit for Brewton projects.

Basement Zone HVAC Load Calculation Details

The basement, configured as a single zone in Revit, handles high-moisture areas like the swimming pool and gym, leading to elevated latent loads. The VAV system adjusts airflow dynamically, with no outdoor air in base simulations to prioritize internal dehumidification.

  • Cooling Load Breakdown: Total peak cooling load reaches 155,174 Btu/hr, with sensible load at 43,533 Btu/hr (instant) and 2,980 Btu/hr (delayed), and latent load dominating at 90,285 Btu/hr. Envelope contributions are minimal (-2,537 Btu/hr delayed sensible from infiltration and walls), while internal gains (people, lights, equipment) account for 145,600 Btu/hr or 94.4% of the subtotal. References ASHRAE 90.1 for load densities, emphasizing dehumidification to manage pool evaporation.
  • Heating Load Breakdown: Peak heating is low at 55,314 Btu/hr total, focused on electric resistance coils for quick response in enclosed spaces. Sensible heating dominates, with minimal latent needs.
  • Psychrometric Conditions: At peak time (9/21 17:00), outdoor air is at 92.7°F dry bulb (DB) and 0.0139 humidity ratio, while zone DB is 73.9°F. Entering coil DB is 73.9°F, leaving at 55.0°F for effective cooling. Coil air flow is 3,109.278 ft³/min, with 0.00% outdoor air—explaining the high internal latent focus per ASHRAE 62.1 ventilation rates.

This zone's high latent load (58% of total) highlights the need for strong dehumidification in Revit modeling.

Ground Floor Zone HVAC Load Calculation Details

As a single zone in Revit, the ground floor includes living areas like bedrooms and kitchen, with VAV ensuring even distribution. Loads are moderate, balancing occupant and appliance heat.

  • Cooling Load Breakdown: Total peak cooling is 35,093 Btu/hr, comprising 14,558 Btu/hr sensible (instant), 13,064 Btu/hr delayed sensible, and 7,460 Btu/hr latent. Envelope subtotal is 1,621 Btu/hr sensible and 10,150 Btu/hr delayed, while internal gains add 12,946 Btu/hr (7.5% of total). No system losses noted, per ASHRAE 90.1 guidelines for residential spaces.
  • Heating Load Breakdown: Heating total is approximately 35,093 Btu/hr (mirroring cooling structure), using variable volume for efficiency, with electric coils handling peak demands.
  • Psychrometric Conditions: Peak at 6/17 13:30 shows outdoor DB 95.5°F and humidity ratio 0.0136. Zone DB is 74.8°F, entering coil 74.8°F, leaving 55.0°F. Air flow rate is 1,283.372 ft³/min at 0.00% outdoor air, aligning with ASHRAE 62.1 for low-activity ventilation.

The balanced loads (21% solar contribution) make this zone ideal for energy-efficient VAV control in Revit.

First Floor Zone HVAC Load Calculation Details

The first floor, a single zone in Revit, mirrors the ground floor layout but accounts for higher solar exposure. VAV boxes optimize airflow for bedrooms and lounges.

  • Cooling Load Breakdown: Peak total is 43,454 Btu/hr, with 16,356 Btu/hr instant sensible, 18,603 Btu/hr delayed sensible, and 8,495 Btu/hr latent. Envelope drives 16,696 Btu/hr (38.4%), internal gains 23,386 Btu/hr (53.8%). Sizing adjustments reduce by 36 Btu/hr, referencing ASHRAE 90.1 for accurate equipment sizing.
  • Heating Load Breakdown: Total heating aligns at 43,454 Btu/hr, emphasizing electric resistance for variable demands in upper levels.
  • Psychrometric Conditions: At peak (6/21 18:00), outdoor DB is 94.8°F with 0.0136 humidity ratio. Zone DB 74.8°F, entering coil 74.8°F, leaving 55.0°F. Coil flow is 1,663.310 ft³/min, 0.00% outdoor air, per ASHRAE 62.1 standards.

Solar gains (18.9%) underscore the need for shading in Revit simulations.

Total HVAC Loads and Tonnage Recommendations

Combining all zones, the home's total cooling load is approximately 233,721 Btu/hr (basement 155,174 + ground 35,093 + first 43,454). Sensible loads total ~74,631 Btu/hr (instant) and ~34,647 Btu/hr (delayed), while latent is ~106,240 Btu/hr—high due to basement moisture.

🔹 Tonnage Calculation Explained: In HVAC load calculation using Revit, 1 ton equals 12,000 Btu/hr. For this Brewton design:

  • Basement: 155,174 / 12,000 ≈ 12.93 tons (oversize slightly to 13-14 tons for latent handling).
  • Ground Floor: 35,093 / 12,000 ≈ 2.92 tons (recommend 3 tons).
  • First Floor: 43,454 / 12,000 ≈ 3.62 tons (recommend 4 tons).
  • Whole Home: ~19.48 tons total. Since separate air systems per zone, select individual units rather than one central. Add 10-20% buffer for peaks, per ASHRAE recommendations.

For external (condensing) units, choose heat pumps or ACs rated for humid climates—e.g., 14-16 SEER2 efficiency. Internal (evaporator/AHU) units should match, with VAV boxes for zoning.

Equipment Placement Recommendations

💡 Optimal Placement Strategy:

  • External Units: Place condensing units on ground level outside, in shaded northern or eastern spots to reduce heat gain. Ensure 2-3 ft clearance for airflow, elevated on pads to avoid flooding—common in Brewton setups.
  • Internal Units: AHUs in utility closets or basements per floor (basement AHU near pool for dehumidification, ground/first in attics or closets). VAV boxes at duct branches for zone control.
  • Ductwork: Route through ceilings or walls, insulated to R-8 minimum per ASHRAE 90.1, minimizing bends for efficiency.

This setup reduces noise and maintenance access issues💡